Shadowing a Volume
Configuring a Shadow-Copy Rule (Source Switch)
15-8 CLI Storage-Management Guide
Configuring a Shadow-Copy Rule (Source Switch)
The final step in volume shadowing is to create a shadow-copy rule. A shadow-copy
rule replicates the fileset in the source volume over to the shadow volume; if a file
changes later, that file is replicated again. If a file is deleted, then its copy is also
deleted. From gbl-ns-vol mode (in the source volume), use the
shadow-copy-rule
command to create a shadow-copy rule:
shadow-copy-rule name
where name (1-64 characters) is a name you choose for this rule.
The CLI prompts you for confirmation before creating the new rule; enter yes to
continue. This places you into gbl-ns-vol-shdwcp mode, where you must identify the
source fileset and the target shadow volume, make a schedule for the rule, then enable
the rule. There are also several optional commands in this mode.
For example, the following command sequence creates a shadow-copy rule,
“DRrule,” for the “/acct” volume. Like the previous example, this occurs on the
“bstnA6k” switch:
bstnA6k(gbl)# namespace wwmed
bstnA6k(gbl-ns[wwmed])# volume /acct
bstnA6k(gbl-ns-vol[wwmed~/acct])# shadow-copy-rule DRrule
This will create a new policy object.
Create object 'DRrule'? [yes/no] yes
bstnA6k(gbl-ns-vol-shdwcp[wwmed~/acct~DRrule])# ...
Identifying the Source Fileset
The next step in configuring a shadow-copy rule is to identify the source fileset. The
shadow-copy rule keeps replicating all files from the source fileset onto the shadow
volume. From gbl-ns-vol-shdwcp mode, use the
from fileset command to specify a
source fileset:
from fileset fileset-name
where fileset-name (1-64 characters) identifies the source fileset.